304 research outputs found

    Impact of diabetes mellitus on ventricular structure, arterial stiffness, and pulsatile hemodynamics in heart failure with preserved ejection fraction

    Get PDF
    Background-Heterogeneity in the underlying processes that contribute to heart failure with preserved ejection fraction (HFpEF) is increasingly recognized. Diabetes mellitus is a frequent comorbidity in HFpEF, but its impact on left ventricular and arterial structure and function in HFpEF is unknown. Methods and Results-Weassessed the impact of diabetesmellitus on left ventricular cellular and interstitial hypertrophy (assessedwith cardiacmagnetic resonance imaging, including T1mapping pregadolinium and postgadolinium administration), arterial stiffness (assessed with arterial tonometry), and pulsatile arterial hemodynamics (assessed with in-office pressure-flow analyses and 24-hour ambulatory monitoring) among 53 subjects with HFpEF (32 diabetic and 21 nondiabetic subjects). Despite few differences in clinical characteristics, diabetic subjects with HFpEF exhibited a markedly greater left ventricular mass index (78.1 [95% CI, 70.4-85.9] g versus 63.6 [95% CI, 55.8-71.3] g; P=0.0093) and indexed extracellular volume (23.6 [95% CI, 21.2-26.1] mL/m(2) versus 16.2 [95% CI, 13.1-19.4] mL/m(2); P=0.0008). Pronounced aortic stiffening was also observed in the diabetic group (carotid-femoral pulse wave velocity, 11.86 [95% CI, 10.4-13.1] m/s versus 8.8 [95% CI, 7.5-10.1] m/s; P=0.0027), with an adverse pulsatile hemodynamic profile characterized by increased oscillatory power (315 [95% CI, 258-373] mWversus 190 [95% CI, 144-236] mW; P=0.0007), aortic characteristic impedance (0.154 [95% CI, 0.124-0.183] mmHg/mL per second versus 0.096 [95% CI, 0.072-0.121] mm Hg/mL per second; P=0.0024), and forward (59.5 [95% CI, 52.8-66.1] mm Hg versus 40.1 [95% CI, 31.6-48.6] mm Hg; P=0.0010) and backward (19.6 [95% CI, 16.2-22.9] mm Hg versus 14.1 [95% CI, 10.9-17.3] mm Hg; P=0.0169) wave amplitude. Abnormal pulsatile hemodynamics were also evident in 24-hour ambulatory monitoring, despite the absence of significant differences in 24-hour systolic blood pressure between the groups. Conclusions-Diabetes mellitus is a key determinant of left ventricular remodeling, arterial stiffness, adverse pulsatile hemodynamics, and ventricular-arterial interactions in HFpEF

    A unified mechanism for the water hammer pulse and pulsus bisferiens in severe aortic regurgitation: Insights from wave intensity analysis

    No full text
    The carotid bisferiens pulse and the radial water hammer pulse are typical of severe chronic aortic regurgitation. Little is known about the mechanism of these classic cardiovascular signs identified on physical examination. We report the first characterization of these abnormal pulse patterns using wave intensity analysis (WIA) in a patient with severe aortic regurgitation. We demonstrate that an abnormally pronounced forward-traveling mid-systolic suction wave, which immediately followed the initial forward-traveling compression wave from ventricular contraction, explained these pulse patterns. This suction wave likely resulted from blood inertia, arising from a ventricle ejecting a very large stroke volume into a vasodilated arterial tree. Our report demonstrates a novel pulsatile hemodynamic mechanism that unifies the pathogenesis of the bisferiens pulse and the water-hammer pulse in severe aortic regurgitation. (C) 2017 Association for Research into Arterial Structure and Physiology. Published by Elsevier B.V. All rights reserved

    Aging is associated with an earlier arrival of reflected waves without a distal shift in reflection sites

    Get PDF
    Background-Despite pronounced increases in central pulse wave velocity (PWV) with aging, reflected wave transit time (RWTT), traditionally defined as the timing of the inflection point (T-INF) in the central pressure waveform, does not appreciably decrease, leading to the controversial proposition of a "distal-shift" of reflection sites. T-INF, however, is exceptionally prone to measurement error and is also affected by ejection pattern and not only by wave reflection. We assessed whether RWTT, assessed by advanced pressure-flow analysis, demonstrates the expected decline with aging. Methods and Results-We studied a sample of unselected adults without cardiovascular disease (n=48; median age 48 years) and a clinical population of older adults with suspected/established cardiovascular disease (n=164; 61 years). We measured central pressure and flow with carotid tonometry and phase-contrast MRI, respectively. We assessed RWTT using wave-separation analysis (RWTTWSA) and partially distributed tube-load (TL) modeling (RWTTTL). Consistent with previous reports, T-INF did not appreciably decrease with age despite pronounced increases in PWV in both populations. However, aging was associated with pronounced decreases in RWTTWSA (general population -15.0 ms/decade, P<0.001; clinical population -9.07 ms/decade, P=0.003) and RWTTTL (general -15.8 ms/decade, P<0.001; clinical -11.8 ms/decade, P<0.001). There was no evidence of an increased effective reflecting distance by either method. TINF was shown to reliably represent RWTT only under highly unrealistic assumptions about input impedance. Conclusions-RWTT declines with age in parallel with increased PWV, with earlier effects of wave reflections and without a distal shift in reflecting sites. These findings have important implications for our understanding of the role of wave reflections with aging

    Isosorbide dinitrate, with or without hydralazine, does not reduce wave reflections, left ventricular hypertrophy, or myocardial fibrosis in patients with heart failure with preserved ejection fraction

    Get PDF
    Background-Wave reflections, which are increased in patients with heart failure with preserved ejection fraction, impair diastolic function and promote pathologic myocardial remodeling. Organic nitrates reduce wave reflections acutely, but whether this is sustained chronically or affected by hydralazine coadministration is unknown. Methods and Results-We randomized 44 patients with heart failure with preserved ejection fraction in a double-blinded fashion to isosorbide dinitrate (ISDN; n=13), ISDN+hydralazine (ISDN+hydral; n=15), or placebo (n=16) for 6months. The primary end point was the change in reflection magnitude (RM; assessed with arterial tonometry and Doppler echocardiography). Secondary end points included change in left ventricular mass and fibrosis, measured with cardiac magnetic resonance imaging, and the 6-minute walk distance. ISDN reduced aortic characteristic impedance (mean baseline=0.15 [95% CI, 0.14-0.17], 3 months=0.11 [95% CI, 0.10-0.13], 6 months=0.10 [95% CI, 0.08-0.12] mmHg/mL per second; P=0.003) and forward wave amplitude (P-f, mean baseline=54.8 [95% CI, 47.6-62.0], 3 months=42.2 [95% CI, 33.2-51.3]; 6 months=37.0 [95% CI, 27.2-46.8] mmHg, P=0.04), but had no effect on RM (P=0.64), left ventricular mass (P=0.33), or fibrosis (P=0.63). ISDN+hydral increased RM (mean baseline=0.39 [95% CI, 0.35-0.43]; 3 months=0.31 [95% CI, 0.25-0.36]; 6 months=0.44 [95% CI, 0.37-0.51], P=0.03), reduced 6-minute walk distance (mean baseline=343.3 [95% CI, 319.2-367.4]; 6 months=277.0 [95% CI, 242.7-311.4] meters, P=0.022), and increased native myocardial T1 (mean baseline=1016.2 [95% CI, 1002.7-1029.7]; 6 months=1054.5 [95% CI, 1036.5-1072.3], P=0.021). A high proportion of patients experienced adverse events with active therapy (ISDN=61.5%, ISDN+hydral=60.0%; placebo=12.5%; P=0.007). Conclusions-ISDN, with or without hydralazine, does not exert beneficial effects on RM, left ventricular remodeling, or submaximal exercise and is poorly tolerated. ISDN+hydral appears to have deleterious effects on RM, myocardial remodeling, and submaximal exercise. Our findings do not support the routine use of these vasodilators in patients with heart failure with preserved ejection fraction

    Arterial properties as determinants of left ventricular mass and fibrosis in severe aortic Stenosis : findings from ACRIN PA 4008

    No full text
    Background-The role of arterial load in severe aortic stenosis is increasingly recognized. However, patterns of pulsatile load and their implications in this population are unknown. We aimed to assess the relationship between the arterial properties and both (1) left ventricular remodeling and fibrosis and (2) the clinical course of patients with severe aortic stenosis undergoing aortic valve replacement (AVR). Methods and Results-We enrolled 38 participants with symptomatic severe aortic stenosis scheduled to undergo surgical AVR. Aortic root characteristic impedance, wave reflections parameters (reflection magnitude, reflected wave transit time), and myocardial extracellular mass were measured with cardiac magnetic resonance imaging and arterial tonometry Cardiac magnetic resonance imaging was repeated at 6 months in 30 participants. A reduction in cellular mass (133.6 versus 113.9 g; P=0.002) but not extracellular mass (42.3 versus 40.6 g; P=0.67) was seen after AVR. Participants with higher extracellular mass exhibited greater reflection magnitude (0.68 versus 0.54; P=0.006) and lower aortic root characteristic impedance (56.3 versus 96.9 dynes/s per cm(5); P=0.006). Reflection magnitude was a significant predictor of smaller improvement in the quality of life (Kansas City Cardiomyopathy Questionnaire score) after AVR (R=-0.51; P=0.0026). The 6-minute walk distance at 6 months after AVR was positively correlated with the reflected wave transit time (R=0.52; P=0.01). Conclusions-Consistent with animal studies, arterial wave reflections are associated with interstitial volume expansion in severe aortic stenosis and predict a smaller improvement in quality of life following AVR. Future trials should assess whether wave reflections represent a potential therapeutic target to mitigate myocardial interstitial remodeling and to improve the clinical status of this patient population

    Beta-Blocker Use Is Associated With Impaired Left Atrial Function in Hypertension

    Get PDF
    BACKGROUND: Impaired left atrial (LA) mechanical function is present in hypertension and likely contributes to various complications, including atrial arrhythmias, stroke, and heart failure. Various antihypertensive drug classes exert differential effects on central hemodynamics and left ventricular function. However, little is known about their effects on LA function. METHODS AND RESULTS: We studied 212 subjects with hypertension and without heart failure or atrial fibrillation. LA strain was measured from cine steady-state free-precession cardiac MRI images using feature-tracking algorithms. In multivariable models adjusted for age, sex, race, body mass index, blood pressure, diabetes mellitus, LA volume, left ventricular mass, and left ventricular ejection fraction, beta-blocker use was associated with a lower total longitudinal strain (standardized beta=-0.21; P=0.008), and lower LA expansion index (standardized beta=-0.30; P \u3c 0.001), indicating impaired LA reservoir function. Beta-blocker use was also associated with a lower positive strain (standardized beta=-0.19; P=0.012) and early diastolic strain rate (standardized beta=0.15; P=0.039), indicating impaired LA conduit function. Finally, beta-blocker use was associated with a lower (less negative) late-diastolic strain (standardized beta=0.15; P=0.049), strain rate (standardized beta=0.18; P=0.019), and a lower active LA emptying fraction (standardized beta=-0.27; P\u3c 0.001), indicating impaired booster pump function. Use of other antihypertensive agents was not associated with LA function. CONCLUSIONS: Beta-blocker use is significantly associated with impaired LA function in hypertension. This association could underlie the increased risk of atrial fibrillation and stroke seen with the use of beta-blockers (as opposed to other antihypertensive agents) demonstrated in recent trials

    Measurement of the B0 Lifetime and Oscillation Frequency using B0->D*+l-v decays

    Full text link
    The lifetime and oscillation frequency of the B0 meson has been measured using B0->D*+l-v decays recorded on the Z0 peak with the OPAL detector at LEP. The D*+ -> D0pi+ decays were reconstructed using an inclusive technique and the production flavour of the B0 mesons was determined using a combination of tags from the rest of the event. The results t_B0 = 1.541 +- 0.028 +- 0.023 ps, Dm_d = 0.497 +- 0.024 +- 0.025 ps-1 were obtained, where in each case the first error is statistical and the second systematic.Comment: 17 pages, 4 figures, submitted to Phys. Lett.

    Measurement of the partial widths of the Z into up- and down-type quarks

    Full text link
    Using the entire OPAL LEP1 on-peak Z hadronic decay sample, Z -> qbarq gamma decays were selected by tagging hadronic final states with isolated photon candidates in the electromagnetic calorimeter. Combining the measured rates of Z -> qbarq gamma decays with the total rate of hadronic Z decays permits the simultaneous determination of the widths of the Z into up- and down-type quarks. The values obtained, with total errors, were Gamma u = 300 ^{+19}_{-18} MeV and Gamma d = 381 ^{+12}_{-12} MeV. The results are in good agreement with the Standard Model expectation.Comment: 22 pages, 5 figures, Submitted to Phys. Letts.
    • …
    corecore